Megger RCDT320 RCD Tester

SKU: MEGRCD2
Over 3 In Stock
Reward Points: 624 [?]

  • Compatible with many different RCD types

  • DC testing of RCDs

  • Includes calibration certificate

£490.00
Save £178.00
£312.00
£374.40 (Inc. VAT)

Login / Sign Up for Member Discount.
Why do I need a calibration?

Found it Cheaper? Found it Cheaper? Price Match
Need Help? Need Help? Contact Us

Megger RCDT320 RCD Tester

Click to enlarge
  • Description

Megger RCDT320 RCD Tester Details

The mid-range model in Megger's RCDT300 series, the RCDT320 can be used on more RCD types than its lesser counterpart, the RCDT310 and comes with a larger selection of features (the differences between each model in the series are outlined in the tech specs section below).

With the RCDT320, it's easy to test RCDs and make sure they're working as intended. It can be used to perform 1/2 I, 1 x I and 5 x I tests on RCDs rated at 30mA, 100mA, 300mA and 500mA (suitable for both general and selective time delayed RCDs) and comes with a special mode for testing those residual current devices rated at 10mA and 1000mA.

The main difference between this product and the RCDT310 is the inclusion of auto testing and ramp testing. The former of these automatically cycles through testing procedures and can be used for hands-free testing while the latter gradually increases test current over a time period until the RCD trips (all relevant information for these tests can be viewed back directly on the tester).

Megger RCDT320 RCD Tester Key Features

  • Performs 1/2 I, 1 x I and 5 x I tests on RCDs rated at 30mA, 100mA, 300mA and 500mA
  • Suitable for use with both general and selective (time-delayed) RCD types
  • Also suitable for testing RCDs rated at 10mA and 1000mA
  • DC RCD testing
  • Selectable polarity - test at 0 or 180°
  • Measurements of touch voltage at the start of the test (with selectable voltage inhibit of 25V or 50V)
  • Rubber-armoured casing - protects the tester from harm at all times in even the most arduous industrial environments
  • Rigid display cover - folds down and protects the screen and tester functions when not in use
  • Colour-coded ranges - easily choose what you need (user guide also included in tester lid)
  • Ramp testing - current level is slowly increased until the RCD trips
  • Automatic testing - all this mode requires is you to reset the RCD each time the test completes. All results are stored on the meter for reference

What's Included?

  • Megger RCDT320 RCD Tester
  • Mains Plug Test Lead (BS1363)
  • 2-Wire Test Lead With Prods and Clips

Accessories

There are a number of accessories available for the Megger RCDT320 RCD Tester. Please contact our sales team for further information or to add an item listed below to an order. 

Our SKU Megger's Part Code Product 
MEGRCDA1 6231-601 UK Mains Plug Test Leadset 3-pin 1 wire (BS1363 plug)
MEGLTA2 1001-883 Test lead set 3-wire Red/Black/Green with prods/clips (exposed tip)  
1001-976 1003-132B Test Lead Set Red/Green Unfused (Boxed)  
1000-562 1000-562 Test Lead Replacement Probe Cap [Clear] Bag of 20  
6220-810 1004-323B SIA10 Socket Interface Adaptor UK to 3 Leads x 4mm (Boxed)
1005-469 1005-469 SIA10 Socket Interface Adaptor LTW  
1004-610 1004-610 Lead USB Type A  to Type B 1.8m Data/Printer Cable
1007-003 1007-003 Blow Moulded Case Catch - Pack of 10  
1007-167 1007-167 Blow Moulded Case MIT/LT/RCDT 300 Series  
Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Technical Specs

Megger RCDT300 Range Differences

Model NumberRCD310RCDT320RCDT330
1/2 I, 5I RCD Trip Time Test
Selective Breakers
DC Breakers (1/2 I, I, 5I)
30, 100, 300, 500mA RCDs
10mA/1A RCDs -
RCD Trip Current Test (RAMP) -
Auto Sequence Test -
0/180° Polarity Selection
Touch Voltage Display Inhibit (Selectable)
Max Touch Voltage (25V/50V)
Operating Range 100 to 280V - -
Operating Range 50 to 280V -
Programmable RCDs - -
Frequency Measurement -
3-Phase Safe
Large, Clear Display
Backlight -
Battery Status Indication
Auto Power Down
Fuse Blown Indication
IP54 Weatherproof
Result Storage - -
Downloadable - -
USB Interface - -
IEC61010-1 CAT III 300V
EN61557

Megger RCDT300 Series Technical Specifications

RCD Test Ranges (to EN61557-6) 
Supply Voltage RCDT310 100 V - 280 V 45 Hz to 65 Hz RCDT320 50 V - 280 V 45 Hz to 65 Hz
RCDT330 50 V - 280 V 45 Hz to 65 Hz
Minimum voltage 71 V for 300 mA RCDs, 100 V for 500 mA RCDs and 205 V for 1000 mA RCDs
Test Current Accuracy 
No Trip Test (1/2I) –8% to –2%
Trip Test (I, 5I) +2% to +8%
Trip Time ±1% ±1ms
Voltage Measurement (All Models)
Range (AC) 0 V - 300 V 25 Hz to 450 Hz
Accuracy ±2% ±2 digits
Frequency (RCDT320/RCDT330 Only) 
Range 25 Hz to 450 Hz
Accuracy 25.0 Hz to 199.9 Hz ±0.1 Hz
200 Hz to 450 Hz ±1 Hz
Fault (Touch) Voltage 
Displayed Range 0 V to 50 V
Error +5%/+15% ±0.5 V
Programmable RCD Step Increments 10 mA to 50 mA - 1 mA steps
50 mA to 500 mA - 5 mA steps
500 mA to 1000 mA - 10 mA steps
Test Result Storage (RCDT330 Only) 
Job Number 256 locations
Distribution Board Number 99 locations
Circuits 99 locations
Phases P1, P2, P3
Other Last recorded result may be recalled to the display. All data can
be downloaded to a PC using Download Manager (supplied) or
Megger Powersuite Professional Windows software
Temperature and Humidity
Operating Range -5°C to +40°C
Operating Humidity 3% R.H. at +40°C max.
Storage Range -25°C to +70°C
Maximum Altitude 2000m
Environmental Protection IP54
Safety 
Requirements Meets the requirements of IEC61010-1 Cat III 300 V phase to
earth.
IEC61557 Complies with the following parts of EN61557, Electrical safety
in low voltage systems up to 1000 V ac and 1500 V dc-
Equipment for testing, measuring or monitoring of protective
measures:
Part1-General Requirements
Part4-Residual current devices
Power Supply 
Batteries 8 x 1,5 V cells IEC LR6 type (AA alkaline).
Rechargeable 8 x 1.2 V NiCd or NiMH cells.
Battery Life 2000 consecutive tests
Weight and Dimensions 
Weight All units 980 gms
Dimensions All units 203 x 148 x 78 mm
E.M.C In accordance with IEC61326-1
Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Reviews

We'd really appreciate it if you'd review this product

Write Your Own Review for Megger RCDT320 RCD Tester

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality