Fluke

Fluke 43b Power Quality Analyser (Analyzer)

SKU: Fluke 43B
Discontinued
Reward Points: 5660 [?]

  • Power quality analyser, oscilloscope, multimeter and recorder all in one tool

  • Easy to use - integrates seamlessly into your system and logs everything

  • Extensive memory

£2,830.00
£3,396.00 (Inc. VAT)

Login / Sign Up for Member Discount.
ITEM IS UNAVAILBALE
Please Contact Us for more information.

Ex Demo Available Ex Demo Available
Found it Cheaper? Found it Cheaper? Price Match
Need Help? Need Help? Contact Us

fluke 43b power quality analyzer single phase

Click to enlarge
  • Description

Fluke 43b Power Quality Analyser (Analyzer) Details

The Fluke 43b Power Quality Analyser/Analyzer is the only analysis tool you need to easily track down all your power and related problems.

The Fluke 43B is the engineer’s choice for diagnosing and troubleshooting power quality and general equipment failures throughout industry.

The Fluke 43b all-in-one Power Quality Tester comprises of the following features:

  • Power Quality Analyser (Analyzer)
  • The Fluke 43b measures power (W, VA, VAR) and power factor (PF, DPF)
  • Calculates power and power factor on balanced 3-phase loads
  • Voltage, current and power harmonics up to the 51st
  • Measures sags and swells on a cycle-by-cycle basis for up to 24 hours
  • Automatically captures up to 40 transients as fast as 40 ns
  • Measures motor inrush and analyses using cursors
  • Covers broad frequency range (10 to 400 Hz)

Oscilloscope Dual-channel scope

Up to 20 MHz bandwidth with the Fluke 43b Voltage Probe
Connect and View” automatic triggering for an instant stable waveform display
On-screen cursors to help analyse signals

Multimeter Measures resistance, continuity and capacitance, and tests diodes

Measures temperature with the Fluke 43b Temperature Probe (Fluke 61 IR Thermometer comes supplied)

Fluke 43b Recorder records up to 2 parameters for up to 16 days

All parameters measured can be recorded including V/A/Hz, all aspects of power and harmonics and all scope measurements

Ease-of-use

Get immediately inside your power system by simply clicking through the most commonly used power quality modes with just a simple keystroke
Just choose the application from the Fluke 43b menu and it sets-up automatically
20 memories for storage of screens and data

General Fluke 43b Power Quality Analyser (Analyzer) features:

  • Calculates three-phase power on balanced loads from a single-phase measurement
  • Measures power harmonics, and captures voltage sags, transients, and inrush currents (see below)
  • Monitoring functions help track intermittent problems and power system performance
  • Fluke 43b menus use familiar electrical terminology
  • Toggle through the most commonly used power quality modes with a single keystroke
  • Records two selectable parameters for up to 16 days
  • 20 measurement memories to save/recall screens and data with cursor readings
  • FlukeView Software can log harmonics and all other readings over time
  • FlukeView Software provides a complete harmonics profile up to the 51st harmonic
  • Measures resistance, diode voltage drop, continuity, and capacitance
  • NIMH Battery provides extended operating time of 6.5 hours
  • Complete Fluke 43b package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
  • Power Quality Analyser: Harmonics
  • Fluke 43b measures voltage, current, and power harmonics
  • Up to 51st harmonic
  • Total harmonic distortion (THD)
  • Phase angle of individual harmonics
  • Power Quality Analyser: Power
  • Fluke 43b measures one and three phase power on balanced loads
  • Watts, power factor, displacement power factor, VA and VAR
  • Voltage and current waveforms

Power Quality Analyser: Three phase
Fluke 43b has on-screen graphics which show you how to set up 3-phase power measurements

Power Quality Analyser: Sags and swells

Fluke 43b continuously measure volts and current on a cycle-by-cycle basis for up to 16 days
Use cursors to read time and date of sags and swells

Power Quality Analyser: Transients

Fluke 43b can catch voltage transients and waveform distortion

  • Catch and save up to 40 transients
  • Correlate the cause of transient with time and date stamps

Power Quality Analyser: Volts/Ampères/Hertz

Fluke 43b measures voltage and current waveforms

  • True RMS voltage and current
  • Frequency

FlukeView Software

  • FlukeView Power Quality Tester Software (included in this Fluke 43b kit)
  • Capture measurement screens and data for professional-looking reports
  • Log readings to your computer disk drive
  • Log harmonics data over time to create a complete harmonics profile
  • Works with Windows word processing, spreadsheet and analysis software
  • Windows compatible

Fluke 43b Power Quality Analyser (Analyzer) kit includes:

  • Fluke 43b Power Quality Analyser (Analyzer)
  • AC20 Industrial Test Clips
  • BB120 Banana-to-BNC Adapter
  • BP120MH Ni-MH Battery Pack (installed)
  • PM 8907 Battery Charger/Line Voltage Adapter
  • TL24 Test Leads
  • TP4 Slim Reach Test Probe Set (4 mm)
  • Fluke 43b Users Manual / Application Guide (CD-ROM)
  • Getting started booklet
  • + Fluke 61 IR Thermometer
  • + VPS40 Voltage Probe
  • i400s AC Current Clamp (400 A)
  • AB200 Large Jaw Alligator Clips
  • C120 Hard Case
  • OC4USB Interface/Adapter Cable
  • SW43W FlukeView Software for Windows + Power Quality Video
  • TP1 Slim Reach Test Probe Set (flat blade)
  • 3 year warranty on the Fluke 43b, 1 year on accessories
Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Technical Specs

Specifications

Input Characteristics

  • Input impedance 1 MΩ, 20 pF
  • Voltage rating 600V rms, CAT III

V/A/Hz Display

  • True-rms voltage (ac + dc) Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V* Accuracy: ±(1% + 10 counts)
  • True-rms current (ac + dc) Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA Accuracy: ±(1% + 10 counts)
  • Frequency Ranges: 10.0 to 15.0 kHz Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
  • CF Crest factor Ranges: 1.0 - 10.0 Accuracy: ±(5% + 1 count)

Power Display  

  • 1-phase and 3-phase,3 conductor balanced loads
  • Ranges: 250 W - 1.56 GW
  • Accuracy: ±(4% + 4 counts) Fundamental Power
  • Accuracy: ± (2 % + 6 counts) Total Power Range: 0 - 1.0 ,Accuracy: ±0.04
  • DPF Displacement Power Factor, Cos .F Range: 0.25 - 0.9, Accuracy: ±0.04 Range: 0.90 - 1.0 Accuracy: ±0.03
  • H2 Frequency Fundamental, Ranges: 40.0 to 70.0 Hz, Accuracy: ± ([% of reading] + [counts]): 0.5% + 2

Harmonics Display

  • Voltage, Current, Frequency, Ranges: Fundamental to 51st harmonic Accuracy: Fundamental: VA ±(3% + 2 counts) W ±(5% + 2 counts)
  • 2 to 31st harmonic: VA ±(5% +3 counts) W ±(10% +10 counts)
  • 32 to 51st harmonic: VA ±(15% +5 counts) W ±(30% +5 counts)
  • Frequency Fundamental, Ranges: 40 Hz to 70 Hz, Accuracy: ±0.25 Hz
  • Phase Range: V, A (between Fundamental & Harmonics) Accuracy: ±3º to ±15º Range: W (between Voltage Fundamental & Current Harmonics) Accuracy: ±5º to ±15º
  • K-factor (Current and Power) Range: 1.0 to 30.0 Accuracy: ±10%
  • THD Total Harmonic Distortion, Range: 0.00 - 99.99, Accuracy: ±(3% + 8 counts)
  • Watts, VA, VAR PF Power Factor,

Sags and Swells

  • Recording times: 4 min to 16 days (selectable)
  • Vrms Actual, Vrms max, min(AC + DC) Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts)
  • Arms Actual, Arms max, min (AC + DC) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(2% +10 counts)

Transient Capture

  • Minimum pulse width: 40 ns
  • Useful bandwidth input 1: DC to 1 MHz
  • Number of transients: 40
  • Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference
  • Reference signal: After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting.
  • Vpeak min, Vpeak max at cursor: 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale

R, C, Diode, Continuity

  • Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ
  • Resistance accuracy: ±(0.6% + 5 counts)
  • Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
  • Capacitance accuracy: ±(2% + 10 counts)
  • Diode Ranges: 0 to 3.000 V
  • Diode voltage: Accuracy: ±(2% + 5 counts)
  • Continuity: Beeper on at < 30 Ω ± 5 Ω
  • Max current: 0.5 mA
  • Temperature: °C or °F

Inrush Current

  • Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
  • Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
  • Cursor readings: A peak max at cursor 1 and cursor 2
  • Accuracy: ±5% of full scale
  • Time between cursors: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)

Temperature (with accessory)

  • Range: -100 °C - 400 °C
  • Accuracy: ±(0.5% + 5 counts)

Scope Display

  • Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
  • Time ranges: 20 ns/div to 60 s/div
  • Max sampling rate: 25 MS/s
  • Bandwidth Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads, Current channel [2]: DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp
  • Coupling: AC, DC (10 Hz - 3 dB)
  • Vertical sensitivity: 5 mV/div to 500V/div
  • Vertical resolution: 8 bit (256 levels)
  • Record length: 512 samples per channel
  • Base ranges: 60 S/div to 20 nS/div ± (0.4% + 1 pixel)
  • Timebase modes: Normal, roll, single
  • Pre-trigger: Up to 10 divisions
  • Trigger Source: Input 1 or Input 2 or automatic selection
  • Trigger Mode: Automatic Connect-and-View™, Free Run, and Single Shot
  • Connect-and-View™: Advanced automatic triggering that recognizes signal patterns. Automatically adjusts triggering, timebase and amplitude and displays stable pictures
  • Memories 20 (screens, settings, data)

Recording

  • Recording times: 4 min to 16 days (selectable)
  • Parameters: Choose one or two parameters from one of the groups below: Volts/Ampères/Hertz
  • Power: Watts, VA, VAR, PF, DPF, Frequency, Harmonics, THD, Volts (Fund. & Harmonic), Ampères (F&H) Watts(F&H), Frequency (H), %(H) of total, Phase(H), KF Temperature
  • Resistance: Resistance, Diode, Continuity, Capacitance
  • Scope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor

Environmental Specifications

  • Operating Temperature 0°C to +50°C

Safety Specifications

  • Electrical Safety EN 61010-1 CAT III, 600V. CSA listed

Mechanical & General Specifications

  • Size 232 x 115 x 50 mm
  • Weight 1.1 kg
  • Battery Life Rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous)
  • Shock & Vibration Mil 28800E, Type 3, Class III, Style B
  • Case IP51 (dust, drip, waterproof)
Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Reviews

We'd really appreciate it if you'd review this product

Write Your Own Review for Fluke 43b Power Quality Analyser (Analyzer)

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality