Order &
Advice Line
Teesside 01642 265426 Manchester 0161 6740168
London 0203 8295781 Birmingham 0121 7969657
International +44 203 8295780    
Free Item
Chauvin Arnoux

Chauvin Arnoux CA6117 Multifunction Tester

SKU: P01145460A
Reward Points: 2698 [?]

  • Comprehensive suite of electrical testing functions

  • High definition colour screen

  • Built-in contextual help - ideal for beginner users

£1,602.00
Save £253.00
£1,349.00
£1,618.80 (Inc. VAT)

Login / Sign Up for Member Discount.
Why do I need a calibration?

Found it Cheaper? Found it Cheaper? Price Match
Need Help? Need Help? Contact Us

Chauvin Arnoux CA6117 Multifunction Tester

Click to enlarge

Select a Free Item

  • 30M R2 Extension Wander Test Lead (PVC Cable Reel)
    FREE   £35.00
  • C.K Tools AVIT 5 x Insulated Screwdriver Set
    FREE   £14.74
  • Silvertronic 3 Wire Silicone Test Lead Set
    FREE   £21.95
  • Description

Chauvin Arnoux CA6117 Multifunction Tester Details

An advanced multifunction tester, the Chauvin Arnoux CA6117 includes every function you'll need for testing and working with electrical installations in line with international standards.

One of the only multifunction testers on the market equipped with a high quality, high definition LCD screen, the CA6117 makes it much easier to view back comprehensive testing information and even includes a handy contextual-help function that walks you through each of the settings!

The CA6117 is full of features and can test practically every electrical parameter. Just turn the rotary dial on the front of the tester to quickly and easily change between current/leakage current, harmonics, power, phase sequence, RCD, loop impedance and PFC, line impedance and PSCC, voltage drop, live earth, live selective earth, 3P earth, continuity, insulation, voltage and frequency!

Chauvin Arnoux CA6117 Multifunction Tester Key Features

  • Testing in compliance with international standards: IEC 60364-6, NFC 15-100, VDE 100 and XP C 16-600
  • Contextual help - always get a reliable connection with help diagrams
  • Suitable for all neutral systems (TT, TN, IT)
  • Special type B RCD testing mode with integrated fuse tables
  • Rugged, compact design for use out in the field
  • Large size, full colour high definition LCD screen with backlight
  • Colour coded terminals for ease of use
  • Measure current, harmonics, power, phase sequence, RCD, loop impedance, line impedance, voltage drop, live earth, live selectable earth, 3p earth, continuity, insulation, voltage and frequency
  • Alarm management function
  • Cable compensation

What's Included?

  • Chauvin Arnoux CA6117 Multifunction Tester
  • Carrying Bag
  • Type-2 Mains Power Pack/Charger
  • Li-Ion Battery Pack
  • USB A/B Cable (1.80m)
  • Three-Point Cable (Red, Blue and Green)
  • 3 x Test Probes (Red, Blue and Green)
  • 3 x Crocodile Clips (Red, Blue and Green)
  • 2 x Elbowed-Straight Safety Leads (3m, Red and Black)
  • Three-Point Euro Mains Cable
  • 2P Euro Mains Cable
  • Remote-Control Probe
  • Wrist Strap
  • Scratch-Proof Film (Mounted on Instrument)
  • 4-Point Hands-Free Strap
  • ICT Data Export Software on CD-ROM
  • 6 Operating Manuals on CD (One Per Language)
  • Safety Datasheet
Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Technical Specs

Chauvin Arnoux CA6117 Technical Specifications

Continuity/Resistance 
I Rated / Range / Resolution I > 200 mA / 39.99 Ω/ 0.01Ω / ± (1.5% of measurement + 2 cts)
12 mA / 39.99 Ω & 399.9 Ω / 0.01 & 0.1 Ω /± (1.5% of measurement + 5 cts) with beep
Range / Resolution / Accuracy 4 kΩ/ 1 Ω / ±(1.5 % of measurement + 5 cts) 40 kΩ - 400 kΩ/ 10 Ω - 100 Ω / ±(1.5 % of measurement + 2 cts)
Insulation
Rated Voltage Utest: 50 /100 / 250 / 500 / 1,000 V DC
Range / Resolution / Accuracy 0.01 MΩ to 2 GΩ / 10 kΩ to 1 MΩ / ±(5 % of measurement + 3 cts)
Short Circuit Current ≤ 3 mA
Earth
3P Earth
Range / Resolution / Accuracy
0.50 Ω to 40 Ω/ 0.01 Ω / ±(2 % of measurement + 10 cts) 40 Ω to 15 kΩ / 0.1 Ω to 1 Ω / ±(2 % of measurement + 2 cts )
15 kΩ to 40 kΩ / 10 Ω/ ±(10 % of measurement + 2 cts )
Others Measurement of resistance of auxiliary stakes RH & RS (up to 40 kΩ)
Ufk Complies with SEV 3569
1P Selective Earth
Range / Resolution / Accuracy
0.20 Ω to 39.99 Ω - 40 Ω to 399.9 Ω / 0.01 Ω – 0.1 Ω / ±(10 % of measurement + 10 cts) (ISel via clamp)
Loop Impedance (Zs (L-PE) and Zi (L-N or L-L)) - 1P Live Earth
Live Earth
Installation Voltage / Frequency
90 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz
High Current Mode with Trip
Zs (L-PE) and Zi (L-N or L-L)
Range / Resolution / Accuracy
Max. test current: 7.5 A
(0.050) 0.100 Ω to 0.5 Ω / 0.001 Ω/ ±(10% of measurement + 20 cts) • 0.5 Ω to 3.999 Ω / 0.001 Ω/ ±(5 % of measurement
+ 20 cts) 3.999 to 39.99 Ω/ 0.01Ω / ±(5% of measurement + 2 cts) • 39.99 Ω to 399.99 Ω / 0.1 Ω/ ±(5 % of measurement + 2 cts)
No Trip Mode (Zs (L-PE) only) Test current: 6 mA – 9 mA – 12 mA (as required) 0.20 Ω to 0.99 Ω / 0.01 Ω / ±(15 % of measurement + 10 cts)
1.00 to 1.99 Ω / 0.01 Ω / ±(15 % of measurement + 3 cts) 2.00 to 39.99 Ω / 0.01 Ω / ±(10 % of measurement + 3 cts)
40.00 Ω to 399.9 Ω / 0.1 Ω / ±(5 % of measurement + 2 cts) 400 to 3999 Ω / 1 Ω / ±(5 % of measurement + 2 cts)
Calculation of lk Short Circuit Current
(PFC (Zs)), I Sc PSCC (Zi)
Fault current and short-circuit current: 0.1 A to 20 kA
Integrated Fuse Table Yes
Voltage Drop ΔV%(Zi) -40 % to + 40 %
Others Measurement of the resistive and inductive components of the Zs and Zi impedances
AC and A-Type RCDs
Installation Voltage / Frequency 90 V to 500 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz
IΔn 10/30/100/300/500/650/1,000 mA (90 V – 280 V) or variable - 10/30/100/300/500 mA (280-550 V) or variable
Ramp and pulse test
No-Trip Test at ½ IΔn – Duration: 1,000 ms or 2,000 ms
Ramp Mode 0.2 to 0.5 x IΔn (Uf) / 0.3 x IΔn to 1.06 x IΔn in increments of 3.3 % x IΔn
Trip Time Measurement
Range / Resolution / Accuracy
0.2 to 0.5 x IΔn (Uf) / 0.5 x IΔn / 2 x IΔn (selective) / 5 x IΔn
Pulse: 0 to 500 ms / 0.1 and 1 ms / 2 ms, Ramp mode: 0 to 200 ms / 0.1 ms / 2 ms
B-Type RCDs
Installation Voltage / Frequency 90 V to 275 V / 15.8 Hz to 17.5 Hz and
45 Hz to 65 Hz
IΔn: ramp / pulse 2 x IΔn
pulse 4 x IΔn
10/30/100/300/500 mA
10/30/100 mA with pulse 4 IΔn
Duration: 150 ms with 4 x IΔn or
300 ms with 2 x IΔn
Test in Ramp Mode 0.2 x IΔn to 2.2 x IΔn
Trip test: 2 x IΔn
4 x IΔn
IΔN ≤ 200 mA: 2.2 x 2 x IΔn
IΔN > 200 mA: 1.1 x 2 x IΔn
IΔN ≤ 100 mA: 2.2 x 4 IΔN
Other Measurements
Current by Clamps C177/C177A 5.0 mA to 199.9 A (C177A)
Current by Clamp MN77 1 mA*) 5.0 mA to 19.99 A
Voltage 0 to 550 VAC/DC / DC and 15.8 to 500 Hz
Frequency 10 to 500 Hz
Phase Rotation 20 to 500 VAC
Active Power 0 to 110 kW single-phase - 0 to 330 kW three-phase
Simultaneous display of voltage and current waveforms
Harmonics Voltage and current / up to 50th order / THD-F /THD-R
General Specifications
Display Large 5.7” backlit graphic colour LCD screen, 320 x 240 points
Storage/Communication via USB for data transfer and report creation
Power Supply: Rechargeable Battery Lithium-ion 10.8 V rated 5.8 Ah
Battery Life up to 30 hours
Dimensions/Weight 280 x 190 x 128 mm / 2.2 kg
Protection IP 53 / IK04
EMC IEC 61326-1
Electrical Safety IEC 61010 -1 – 600 V CAT III – 300 V CAT IV – IEC 61557