Beha-Amprobe ACD-14 PLUS Dual Display Clamp Meter

SKU: 3086905
Reward Points: 136 [?]

  • Dual display shows both voltage and current simultaneously

  • Measure temperature, resistance and much more

  • Specially designed thin jaws for difficult applications

£99.00
Save £31.00
£68.00
£81.60 (Inc. VAT)

Login / Sign Up for Member Discount.
Why do I need a calibration?

Found it Cheaper? Found it Cheaper? Price Match
Need Help? Need Help? Contact Us

Amprobe Acd 14Plus Clamp Multimeter 400A

Click to enlarge
  • Description

Beha-Amprobe ACD-14 PLUS Dual Display Clamp Meter Details

Uniquely designed and popular amongst both HVAC and electrical professionals, the Beha-Amprobe ACD-14 PLUS is a clamp meter with a difference. Not only does it perform a wide variety of different measurement functions but this clamp meter also comes with dual displays, allowing it to measure current and voltage simultaneously!

Featuring special thin jaws for use in difficult applications, the Beha-Amprobe ACD-14 PLUS is suitable for clamping onto conductors up to 25mm in diameter. Once clamped on it can measure AC current only from 40A up to a high threshold of 600A and DC/AC voltage from as low as 400mV (only on DC) to 600V (for both AC and DC).

As well as these standard measurement functions the Beha-Amprobe ACD-14 PLUS can be used to measure flame sensors using the micro amp function, can measure capacitance to 3000μF, can measure temperature using a type K thermocouple probe, measure resistance to 40MΩ and can also be used to test continuity, frequency, diode and inrush current.

The ACD-14 PLUS is an autoranging clamp meter.

Beha-Amprobe ACD-14 PLUS Clamp Meter Key Features

  • Dual displays - shows both amperage (current) and voltage simultaneously!
  • Measurements of AC current up to 600A
  • Specially designed thin jaws (5mm thinner than most competitors) for use in difficult applications
  • Microamps measurement mode for use on flame sensors
  • Capacitance measurements to 3000μF
  • Temperature measurements using a type K thermocouple probe
  • Measure AC/DC voltage to 600V
  • Resistance measurements to 40MΩ
  • Continuity buzzer
  • Frequency measurements
  • Diode test
  • Hold and MAX functions
  • Suitable for conductors up to 25mm (1.0") in diameter)
  • Autoranging clamp meter
  • Auto power off function
  • Low battery indicator
  • Rubber, over-moulded casing

What's Included?

  • Beha-Amprobe ACD-14 PLUS Clamp Meter
  • Test Leads
  • Carrying Case
  • Bead Type Thermocouple with Banana Plug
  • User Manual
Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Technical Specs

Key Tech Specs

Cat iiiCat III
600V

StandardsStandards
EN:61010-1, EN:61010-2-032
 

Beha-Amprobe ACD-14 PLUS Technical Specifications

SpecificationsRange
Display 3-3/4 digit 4000 count dual LCD displays
Update Rate 3 second (nominal)
Polarity Automatic
Low Battery Indication Below approx 2.4V
Operating Temperature 0 to 40°C (32 to 104°F)
Relative Humidity Maximum relative humidity: 80% (for temperatures up to 31°C/88°F)
Value decreases linearly to 50% relative humidity at 40°C (104°F)
Altitude Indoor operation below 2000m (6562 ft)
Storage Temperature -20 to 60°C (-4 to 140°F), <80% RH (with battery removed)
Temperature Coefficient Nominal 0.15 x (specified accuracy)/°F @ 0°C - 18°C or 28°C - 40°C (32°F - 64°F or 82°F - 104°F) or otherwise specified
Sensing Average sensing for ACD-14 Plus
Power Supply 2 x 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032)
Battery Life 95 hours approx (in DCV mode)
Power Consumption 2.5mA typical for ACD-14 Plus
Low Battery Indication Below approx 2.4V (battery symbol appears in upper right)
Auto Power Off After being idle for 30 minutes
APO Consumption ACD-14 PLUS: 0.8μA typical expect 25μA typical for temperature function
Safety CE EN61010-1, EN61010-2-032
Pollution degree 2
Transient Protection 6.5kV (1.2/50μs surge) for all models
E.M.C Meets EN61326
Overload Protections RMS ACA clamp-on jaws: AC 600A RMs continuous "+" & "COM" terminals (all functions); 600VDC/VAC
Dimensions L 190mm x W 63mm x H 32mm (7.48" x 2.48" x 1.25")
Weight 204g (0.450lb approx)
Jaw Opening/Conductor Diameter 25mm (1.0") max
Electrical SpecificationsRange
DC Voltage 400.0 mV ± (0.3% rdg + 4 digits)
4.000V, 40.00V, 400.0V ± (0.5% rdg + 3 digits)
600V ± (1.0% rdg + 4 digits)
NMRR: >50dB @ 50/60Hz
CMRR: >120dB @ DC, 50/60Hz, Rs=1kΩ
Input Impedance: 10MΩ, 30pF nominal (1000MΩ for 400.0mV range)
AC Voltage (50Hz - 500Hz) Average Sensing 4.000V, 40.00V, 400.0V ± (1.5% rdg + 5 digits)
600V ± (2.0% rdg + 5 digits)
CMRR: >60dB @ DC to 60Hz, Rs=1kΩ
Input Impedance: 10MΩ, 30pF nominal
AC Current (Clamp-On) [50Hz/60Hz] 40.00A ± (1.5% rdg + 8 digits)
400.0A ± (1.5% rdg + 8 digits)
600A ± (1.5% rdg + 8 digits)*
*Accuracy specified to 600A continuous.
Max/Hold (AC Current Only) Specified accuracy ± 50 digits for changes > 25ms in duration
Ohms 400.0Ω ± (0.8% rdg + 8 digits)
4.000kΩ, 40.00kΩ, 400.0kΩ ± (0.6% rdg + 4 digits)
4.000MΩ ± (1.0% rdg + 4 digits)
40.00MΩ ± (2.0% rdg + 4 digits)
Open Circuit Voltage: 0.4VDC typical
Audible Continuity Tester: Audible threshold: between 10Ω and 120Ω.
Capacitance 500.0nF, 5.000μF, 50.00μF,
500.0μF, 3000μF* ± (3.5% rdg + 6 digits)***
*Additional 50.00nF range accuracy is not specified
**Accuracies with film capacitor or better
***Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low
battery warning voltage of approximately 2.4V
DC μA Range 400μA: ±2.0% rdg + 4 digits (burden voltage: 2.8mV/μA)
2000μA: ±1.5% rdg + 3 digits (burden voltage: 2.8mV/μA)
AC μA (50Hz-500Hz) 400μA: ±2.0% rdg + 5 digits (burden voltage: 2.8mV/μA)
2000μA: ±1.5% rdg + 5 digits (burden voltage: 2.8mV/μA)
Frequency (Voltage Input Only) 400mV - 10Hz to 2kHz (sensitivity: 300mV - accuracy: 0.5% rdg + 4 digits)
4V - 5Hz to 40kHz (sensitivity: 4V - accuracy: 0.5% rdg + 4 digits)
40V - 5Hz to 100kHz (sensitivity: 28mV - accuracy: 0.5% rdg + 4 digits)
400V - 5Hz to 40kHz (sensitivity: 100V - accuracy: 0.5% rdg + 4 digits)
Diode Test Open Circuit Voltage: <1.6VDC
Test Current (Typical): 0.25mA
Temperature (Type K Thermocouple) -20 to 300°C (±2% rdg + 3°C)
301 to 537°C (±3% rdg + 3°C)
-4 to 572°F (±2% rdg + 6°F)
573 to 999°F (±3% rdg + 6°F)