Transmille 2080 16th Edition Calibrator
Product Code: Transmille 2080
PRODUCT DESCRIPTION FOR TRANSMILLE 2080 16TH EDITION CALIBRATOR
The Transmille 2080 unit is a purpose built unit to assist electricians with the requirement of the NICIEC to calibrate all of their 16th Edition Equipment.
Tests...
Insulation & Continuity Testers
RCD Testers
LOOP Testers
Combined Installation Testers
A fully featured test box for use in testing electricians equipment, the 2080 provides a fast solution for the requirement of regular verification of electrical test equipment.
Designed with low cost and portability in mind, the use of the 2080 provides on or off site verification of RCD Testers, LOOP Testers, Continuity and Insulation Testers.
The 2080 is simple to use and provides the following functionality :
2080 - GENERAL
Checking of Insulation Testers
3 high value resistors (1MW, 9.9MW & 99MW) for testing the resistance measurement function.
LED indication of test voltage at 100V 250V 500V 1000V
3 low value resistors ( 0.5W, 2W & 10W) for testing the continuity function.
AC line voltage output for testing voltage measurement
Checking of RCD Testers
Dedicated 13A socket provides functional check of RCD tester operation
3 selectable ranges : 10mA@150ms 30mA@150ms 150mA@30ms
Indicators for Ready Tripped Overcurrent
Checking of LOOP Testers
A functional check of LOOP Testers, allowing direct measurement of supplied loop impedance and supplied loop impedance + 1W via a dedicated 13A socket.
Wiring Check
When connected, the 2080 checkbox will indicate voltage between the following wires *
P-E (Phase to Earth) P-N (Phase to Neutral) N-E (Neutral to Earth)
* Does not detect Neutral to Earth reversal
Certification
Calibration Certificates traceable to UK National Standards or UKAS are available.
2080 - SPECIFICATIONS SUMMARY
LOOP Testers
Supply Loop Supply Loop + 1W : 5%
--------------------------------------------------------------------------------
Insulation Testers
1MW : 9.9MW : 99MW : 1%
Max. Test Voltage 1.2kV
--------------------------------------------------------------------------------
Continuity Testers
0.5W : 2W : 10W : 1% ± 20mW
Max. Current 300mA
--------------------------------------------------------------------------------
RCD Testers
10mA (Nominal) @150ms
30mA (Nominal) @ 150ms
150mA (Nominal) @30ms
Tests...
Insulation & Continuity Testers
RCD Testers
LOOP Testers
Combined Installation Testers
A fully featured test box for use in testing electricians equipment, the 2080 provides a fast solution for the requirement of regular verification of electrical test equipment.
Designed with low cost and portability in mind, the use of the 2080 provides on or off site verification of RCD Testers, LOOP Testers, Continuity and Insulation Testers.
The 2080 is simple to use and provides the following functionality :
2080 - GENERAL
Checking of Insulation Testers
3 high value resistors (1MW, 9.9MW & 99MW) for testing the resistance measurement function.
LED indication of test voltage at 100V 250V 500V 1000V
3 low value resistors ( 0.5W, 2W & 10W) for testing the continuity function.
AC line voltage output for testing voltage measurement
Checking of RCD Testers
Dedicated 13A socket provides functional check of RCD tester operation
3 selectable ranges : 10mA@150ms 30mA@150ms 150mA@30ms
Indicators for Ready Tripped Overcurrent
Checking of LOOP Testers
A functional check of LOOP Testers, allowing direct measurement of supplied loop impedance and supplied loop impedance + 1W via a dedicated 13A socket.
Wiring Check
When connected, the 2080 checkbox will indicate voltage between the following wires *
P-E (Phase to Earth) P-N (Phase to Neutral) N-E (Neutral to Earth)
* Does not detect Neutral to Earth reversal
Certification
Calibration Certificates traceable to UK National Standards or UKAS are available.
2080 - SPECIFICATIONS SUMMARY
LOOP Testers
Supply Loop Supply Loop + 1W : 5%
--------------------------------------------------------------------------------
Insulation Testers
1MW : 9.9MW : 99MW : 1%
Max. Test Voltage 1.2kV
--------------------------------------------------------------------------------
Continuity Testers
0.5W : 2W : 10W : 1% ± 20mW
Max. Current 300mA
--------------------------------------------------------------------------------
RCD Testers
10mA (Nominal) @150ms
30mA (Nominal) @ 150ms
150mA (Nominal) @30ms
PRODUCTS SIMILAR TO TRANSMILLE 2080 16TH EDITION CALIBRATOR
Portable Appliance Safety Services
http://www.pat-services.co.uk EMAIL : info@pat-services.co.uk
FREEPHONE : 0800 247 1600 Sales Office Open : 9am - 6pm FAX : 0870 143 1869