Kewtech KT71 PAT Tester Kit 1
An excellent PAT Testing Starter Kit!
Kewtech KT71 PAT Tester Kit 1 includes:
• Kewtech KT71 PAT Tester
• The Essential Guide to PAT Testing Training DVD (with online examination)
• 500 Passed Labels
• 500 Failed Labels
• 500 Cable Wraps
• 240v Plug to 10amp IEC Lead for testing 240v Extension Cables
• 110v Socket to 10amp IEC Lead for testing 110v Extension Cables
• PAT Testing Log book (to record your test results)
• Delux Carry Case for easy transportation and protection of your PAT Testing Kit! Comes with customisable foam, so you can snugly fit whatever equipment you would like to take on site
Also comes supplied with:
• Mains Lead
• Test Lead/Crocodile Clip
• Instruction Manual
• Soft Carry Case
Easy and Safe Testing - Great for low level users!
The KT71 makes PAT Testing easy and safe. In house maintenance staff who conduct their own yearly PAT Testing and electrical contractors who need to have a PAT testing capability, but for whom it is not core for their business, can easily be trained to use this instrument with complete safety.
LED indictators give visual pass/fail indication with limits set in accordance with the IET (IEE) code of practice. This means that, in most cases, users will not have to interpret the results.
When switching to live testing (in leakage current mode) audible warnings are given that the appliance is about to come live. A double button press is also required to safeguard against inadvertent switching on of an appliance.
Features of the Kewtech KT71:
Class I Test
It automatically goes through the test sequence, for example, it performs the sequence of an earth bond test at 200mA, followed by a check to see whether the user has not forgotten to switch the instrument on, then an insultation test.
The insultation test has a 250V or 500V option and the test sequence also has an option whether a leakage current test is done instead of an insultation test.
This corresponds to the IEE Code of Practice which supports a leakage test where insultation tests cannot be safely conducted.
Class I 20A test
Performs the sequence of an earth bond test at 20A, followed by a check to see whether the user has not forgotten to switch the instrument on, then an insulation test.
The insulation test has a 250V or 500V option and the test sequence has an alternative of a leakage current test instead of the insultation test.
This corresponds to the IEE code of Practice which supports a leakage test where insultation tests cannot be safely conducted or are suspect.
Class II Test
The Class II sequence tests whether the appliance is switched on and then runs an insulation test. A leakage current test (touch current test) can be conducted as an alternative.
Leakage Current (Touch Current) Test
The Leakage Current Test is conducted at mains voltage, a load test and a leakage test is undertaken and the results are shown alternatively on the screen. (Testing at mains voltage gives superior results than instruments that perform this by subsequent leakage tests).
Extension Lead Test
Tests Earth Continuity with 20A test current, insultation and polarity. An extension lead adapter comes with the KT71.